The Master 80 XC self-adhesive reflective film has been specially designed to protect against the detrimental effects of solar exposure, limiting solar heat gain, solar glare and eliminating the effects of fading on polycarbonate and other synthetic materials.
1. Hard scratch resistant layer, for durability and ease of maintenance during window cleaning
2. High optical quality polyester, with anti IR metal particles deposit
3. Half permanent adhesive that will ease the removal of the film from the window
4. High optical quality polyester
5. PS adhesive, glass polymerization within 15 days
6. Protection release liner, disposable after installation
Soapy water solution (ref. 600-F0355 Film on), do not clean for at least a month and do not apply any type of sticker or adhesive on the film.
The silicone should be applied to the perimeter of the film when it is installed externally, to prevent any oxidation. Please read the notice regarding "new warranty for external films"
Data calculated based on film applied to clear glass 3 mm thick (*on double glazing 4-16-4)
Ultraviolet transmission | 1 % |
Visible light transmission | 16 % |
Reflection of external visible light | 62 % |
Reflection of internal visible light | 60 % |
Total solar energy rejected | 89 % |
Total solar energy rejected 2* | 89 % |
Solar ratio : | |
Solar energy reflection | 67 % |
Solar energy absorption | 20 % |
Solar energy transmission | 13 % |
Reduction in Solar Glare | 84 % |
g-value | 0.18 |
u-value | 5.1 |
Heat loss Reduction (Winter) | |
Rejected Infrared (760-2500 nm) | |
Shading coefficient | 0.2 |
Installation type : Exterior | |
Roll length | 30,5 m |
Film composition | PET |
Thickness | 60 μ |
Colour from the outside : SILVER |
Vertical installation and on standard glass surface*
Clear single pane | |
Tinted single pane | |
Reflective tinted single pane | |
Clear double pane | |
Tinted double pane | |
Reflective tinted double pane | |
Gas-filled double pane - Low E | |
STADIP EXT. clear double pane | |
STADIP INT. clear double pane | |
Yes Caution Not recommended |
*Recommendations provided on the basis of a glazed surface covering up to 2.5m², contact us for definitive details or to obtain a thermal chock analysis report. Test compatibility before each installation.
Installation on a "concave" surface is not permitted due to the risk of fire
Non-contractual data. We reserve the right to modify the composition of our films at any time. Consult our warranty documents.